•  Retrait gratuit dans votre magasin Club
  •  7.000.000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous     
  •  Retrait gratuit dans votre magasin Club
  •  7.000.0000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous

Icrp Publication 127

Radiological Protection in Ion Beam Radiotherapy

Y Y Yonekura
Livre broché | Anglais | Annals of the Icrp
315,95 €
+ 631 points
Livraison 2 à 3 semaines
Passer une commande en un clic
Payer en toute sécurité
Livraison en Belgique: 3,99 €
Livraison en magasin gratuite

Description

The goal of external beam radiotherapy is to provide precise dose localisation in the treatment volume of the target with minimal damage to the surrounding normal tissues. Ion beams, such as protons and carbon ions, provide excellent dose distributions due primarily to their finite range, allowing a significant reduction of undesired exposure to normal tissues. Careful treatment planning is required for the given type and localisation of the tumour to be treated in order to maximise the treatment efficiency and minimise the dose to the normal tissues. Radiation exposure in the out-of-field volumes arises from secondary neutrons and photons, particle fragments, and photons from activated materials. These unavoidable doses should be considered from the standpoint of radiological protection of the patient. Radiological protection of medical staff at ion beam therapy facilities requires special attention. Appropriate management and control are required for the therapy equipment and also for the air in the treatment room which can be activated by the particle beam and its secondaries. Radiological protection and safety management should always be in conformity with regulatory requirements. The current regulations for occupational exposures in photon radiotherapy are applicable to ion beam radiotherapy with protons or carbon ions. Ion beam radiotherapy requires, however, a more complex treatment system than conventional radiotherapy, and appropriate training of the staff and suitable quality assurance programme are recommended to avoid possible accidental exposure to the patient, to minimise unnecessary doses to normal tissues and to minimise radiation exposure of staff.

Spécifications

Parties prenantes

Auteur(s) :
Editeur:

Contenu

Nombre de pages :
116
Langue:
Anglais
Collection :

Caractéristiques

EAN:
9781473918818
Date de parution :
17-02-15
Format:
Livre broché
Format numérique:
Trade paperback (VS)
Dimensions :
170 mm x 244 mm
Poids :
195 g

Les avis

Nous publions uniquement les avis qui respectent les conditions requises. Consultez nos conditions pour les avis.